1. Fault Overview
The E-06 fault indicates a deceleration overvoltage, a common issue that can occur during the deceleration process of the SHZHD.V680 variable frequency drive. When the output voltage exceeds the safe range during deceleration, the drive triggers a protection mechanism, leading to equipment shutdown or alarms. This fault is often related to motor load characteristics, parameter settings, and over-excitation control.
2. Fault Cause Analysis
- Improper Over-Excitation Settings: Low over-excitation gain settings can cause the voltage to rise too quickly during deceleration.
- Load Characteristics: Loads with high inertia can generate excessive reverse electromotive force during deceleration.
- Unreasonable Parameter Settings: Short deceleration times can cause the voltage to rise too quickly during deceleration.

3. Solutions
3.1 Adjust Over-Excitation Gain
- Parameter P3-10 (VF Over-Excitation Gain): Increase this value to better suppress voltage rise during deceleration. Recommended range: 0 ~ 200. Gradually increase based on actual conditions until the fault is resolved.
3.2 Optimize Deceleration Time Settings
- Parameter P0-18 (Deceleration Time 1): Extend the deceleration time to make the deceleration process smoother. Gradually increase based on actual load characteristics until the fault is resolved.
3.3 Check Load Characteristics
- If the load has high inertia, additional braking measures, such as adding a braking resistor or using a regenerative system, may be necessary during deceleration.
3.4 Check Motor and Drive Compatibility
- Ensure that the motor and drive parameters are matched to avoid overvoltage issues due to mismatched parameters.
4. Precautions
- Adjust parameters gradually to avoid introducing other issues.
- Conduct trial runs after adjustments to confirm that the fault has been resolved.
- If the problem persists, consult technical support or a professional repair technician for further diagnosis.

5. Conclusion
By appropriately adjusting the over-excitation gain, optimizing deceleration time settings, checking load characteristics, and ensuring motor and drive compatibility, the E-06 deceleration overvoltage fault in the SHZHD.V680 variable frequency drive can be effectively resolved. Proper parameter settings and regular maintenance are key to ensuring the efficient operation of the drive.