Posted on Leave a comment

ABB AC Drive ACS880 Series Firmware Manual User Guide

Introduction

The ABB ACS880 series AC Drives represent a high-performance drive system widely utilized across various industrial applications. To ensure users can efficiently and safely operate this product, this document provides a comprehensive guide to the features and operations of the ACS880 series AC Drives, focusing on the operation panel (control pad), external control settings, and other key functionalities.


ACS-AP-x control panel function navigation diagram

Operation Panel (Control Pad) Functionality

Overview

The operation panel, also known as the control pad, serves as the primary interface for configuring and monitoring the ACS880 AC Drive. This section will detail the functions of the control pad, including how to reset the drive to factory settings, set a password, and remove a password.

Resetting to Factory Settings

To reset the ACS880 AC Drive to its factory settings using the control pad:

  1. Access the Main Menu: Navigate to the main menu on the control pad.
  2. Select Parameters: Locate and select the “Parameters” menu.
  3. Reset to Factory Defaults: Find the option to reset to factory defaults and confirm the action.

Note: Resetting to factory settings will erase all user-defined parameters and configurations. Ensure all necessary settings are backed up before proceeding.

Setting a Password

To protect your drive settings from unauthorized access, you can set a password on the control pad:

  1. Access the Parameters Menu: Navigate to the “Parameters” menu on the control pad.
  2. Locate the Password Setting: Find the parameter related to setting a password.
  3. Enter the Password: Follow the prompts to enter and confirm your desired password.
ACS880-01 default IO connection diagram

Removing a Password

If you need to remove a previously set password:

  1. Access the Parameters Menu: Navigate to the “Parameters” menu on the control pad.
  2. Locate the Password Removal Setting: Find the parameter related to removing the password.
  3. Enter the Current Password: You may be prompted to enter the current password to confirm the removal.
  4. Confirm Removal: Follow the prompts to confirm the password removal.

Setting Up External Control

Overview

External control allows you to start, stop, and adjust the speed of the ACS880 AC Drive via external signals rather than through the control pad. This section will guide you through the necessary wiring and steps to set up external control, including starting and stopping the drive and adjusting its speed via an external potentiometer.

Wiring for Start and Stop

To control the start and stop functions of the ACS880 AC Drive externally, you need to connect the appropriate terminals on the drive:

  1. Locate the Control Terminals: Identify the terminals labeled for start and stop control on the drive.
  2. Wire the Terminals: Connect your external control devices (e.g., pushbuttons, relays) to these terminals according to the required logic (e.g., normally open, normally closed).

Note: Ensure proper polarity and isolation to prevent short circuits and electrical hazards.

Adjusting Speed via External Potentiometer

To adjust the speed of the ACS880 AC Drive using an external potentiometer:

  1. Connect the Potentiometer: Use a suitable potentiometer and connect its terminals to the analog input terminals on the drive designated for speed control.
  2. Configure the Analog Input: Navigate to the “Parameters” menu on the control pad and configure the analog input to accept speed commands from the potentiometer.
  3. Calibrate the Potentiometer: Adjust the potentiometer’s range to match the desired speed range of the drive.

Note: Refer to the drive’s manual for specific parameter settings related to analog input and speed control.


Conclusion

This guide provides a comprehensive overview of the essential functionalities of the ABB ACS880 series AC Drives, focusing on the operation panel and external control settings. By following the steps outlined in this guide, users can efficiently configure and operate their drives, ensuring optimal performance and safety in various industrial applications. Always refer to the drive’s manual for detailed parameter settings and additional features.