INVT Servo SV-DA200 Series Manual User Guide

I. Implementation of Servo JOG Jogging Operation

Implementation Process

Servo JOG (Jogging) operation allows users to manually control the servo motor for short, small movements, primarily used for debugging or precise positioning. The following are the specific steps to implement servo JOG operation:

1. Hardware Connection

  • Connect the Servo Motor: Ensure the servo motor is properly connected to the servo drive, and check that all connecting cables are secure.
  • Control Signal Wiring: According to the CN1 terminal wiring diagram for the DA200 series servo drive, connect the control signal wires to the corresponding CN1 terminals on the servo drive. For JOG operation, typically, servo enable (SON), direction control (e.g., POT, NOT), and jog signal lines need to be connected.

2. Parameter Settings

  • Set the Motor Model: Use parameter P0.001 to set the correct motor model to ensure the drive can recognize the connected motor.
  • Configure JOG-related Parameters:
    • Jogging Speed: Set the jogging speed through parameter P0.05, typically in units of r/min.
    • Digital Input Configuration: In the P3.xx series of parameters, configure the digital input functions for servo enable (SON), forward jog (e.g., FJOG), reverse jog (e.g., RJOG), and other related inputs as needed.

3. Software Operation

  • Enable the Servo: Activate the servo drive by providing a valid signal to the servo enable terminal (SON).
  • Execute JOG Operation: Apply a forward jog (FJOG) or reverse jog (RJOG) signal, and the servo motor will move at the set jogging speed. Control the duration of the jog signal to manage the motor’s movement distance.

Precautions

  • Ensure safety during JOG operations to prevent accidental movements that could cause harm.
  • Check all connecting cables and parameter settings to ensure correct operation.
SV-SD200 Position Mode Standard Wiring Diagram

II. Servo Positioning via External Pulses in Position Control Mode

Implementation Process

In position control mode, precise servo positioning through external pulse signals is a common application. The following are the implementation steps:

1. Hardware Connection

  • Pulse Signal Lines: Connect the pulse signal lines to the pulse input terminals on the servo drive (e.g., PULS+, PULS- on CN1). Depending on requirements, direction signal lines (SIGN+, SIGN-) may also need to be connected.
  • Encoder Feedback Lines (if required): If encoder feedback is used, connect the encoder cables correctly to the corresponding terminals on the servo drive.

2. Parameter Settings

  • Control Mode Selection: Set parameter P0.03 to 0 for position control mode.
  • Pulse Input Configuration:
    • Configure the pulse input form (e.g., differential input or open-collector output) and direction signal settings.
    • Set the electronic gear ratio (e.g., P0.25, P0.26) to convert external pulses into actual motor shaft movements.
  • Position Control-related Parameters:
    • Adjust position loop gains (e.g., P2.02) and other control parameters as needed.
    • Configure software limits (e.g., P0.35, P0.36) to prevent exceeding safe travel ranges.

3. Software Operation

  • Send Pulse Signals: Transmit pulse signals to the servo drive via an upper computer, PLC, or other control system. The number of pulses determines the motor’s movement distance, while the pulse frequency controls the motor’s speed.
  • Monitor Status: Use the servo drive’s display panel or upper computer software to monitor the servo motor’s actual position and speed.

Precautions

  • Ensure pulse signal quality and stability to prevent positioning inaccuracies due to signal interference.
  • Adjust control parameters according to actual needs to achieve optimal control performance.

III. Fault Code Meanings and Solutions

Common Fault Codes and Solutions

  • Er10-4: Emergency Stop
    • Meaning: The emergency stop signal is active.
    • Solution: Check if the emergency stop button or related input signal lines have been triggered accidentally, clear the fault, and re-enable the servo.
  • Er22-0: Position Deviation Fault
    • Meaning: The actual position deviates significantly from the command position.
    • Solution: Inspect the mechanical transmission components for jams or loose connections, adjust position loop gains and other control parameters as needed.
  • Er25-1: Overcurrent Fault
    • Meaning: The motor current exceeds the rated value.
    • Solution: Check if the motor is overloaded, adjust speed or torque loop gains, and ensure the power supply voltage is stable.
  • Er13-1: Undervoltage Fault
    • Meaning: The main circuit supply voltage is too low.
    • Solution: Verify the power supply voltage, troubleshoot line faults, or adjust the power supply voltage.

Precautions

  • When encountering fault codes, first consult the fault code table for specific meanings and then follow the corresponding solutions for troubleshooting.
  • If faults cannot be resolved, promptly contact technical support or professional maintenance personnel for assistance.

By following the steps and precautions outlined above, users can effectively implement INVT Servo DA200 series JOG jogging operation, position control using external pulses, and fault diagnosis and resolution.

Posted on Leave a comment

Repair of INVT P9G9-55kW inverter switch power supply

A 55KW inverter of the Envision suddenly shut down in thunderstorm weather, with no display on the panel, suspected of being damaged by lightning strikes.

Inspection: Both the input rectifier module and the output inverter module are undamaged. The switch power supply has no output, the switch tube is damaged, and the copper foil strip introduced by the power supply and the copper foil strip of the switch tube drain circuit have all detached from the substrate, indicating that this circuit has been subjected to high current shocks.
After replacing the switch tube and oscillation block 3844B, the switch power supply was first sent to an AC 220V rectifier power supply, which did not vibrate and confirmed that there was no short circuit phenomenon; Then send in a 500V DC power supply, and when powered on, the power supply will burn and fuse F1 will be introduced. Power outage measurement inspection, no short circuit phenomenon. After replacing the fuse, power on. When it is below 300V DC, it does not vibrate, but when it is sent to 500V, the fuse still burns. When there is a short circuit fault in the load circuit of the power supply, the power supply often cannot vibrate; It is suspected that there is a short circuit fault in the circuit of the switch tube after the vibration is triggered, but after measurement and inspection, there is indeed no short circuit phenomenon. Maintenance has entered a dead end.
Carefully observe the circuit board of the switch power supply. The approximately 550V DC power supply of the switch power supply is introduced through the main DC circuit, and the circuit board is a double-sided circuit board. The power supply terminal is located at the edge of the circuit board, with a+pole lead copper foil strip on the front and a – pole lead copper foil strip on the back. It was found that there is a “black wire” between the+and – copper foil strips on the edge of the circuit board! Due to humid weather, the insulation of the circuit board is reduced, causing sparks between the+and – copper foil strips and carbonization of the circuit board. When the power supply voltage is below a certain value, it will not break down. When it is above 500V, it will cause the carbonized circuit board to break down and burn out the fuse. The reason for burning the fuse is not due to a short circuit fault in the switch circuit after vibration, but rather caused by carbonization of the circuit board.

Remove carbides from the edges of the circuit board and perform insulation treatment. When fed into 500V, the fuse will no longer burn, but it will not vibrate. Check that the rectifier diode D38 (LL4148) of the 3844B power supply branch has a certain reverse resistance. After replacement, the machine tested normally.
The circuit board is broken down and carbonized after being damp, causing a fuse burning fault, which is also a relatively small fault phenomenon encountered in switch mode power supplies.